A soft start kit lets a 2,200W generator run a 13,500 BTU RV AC by cutting startup surge 65–75%. How it works, install basics, and when it's not enough.

If you want to run your RV’s rooftop air conditioner on a small 2,000–2,500-watt inverter generator, then yes — a soft start kit is the difference between “the compressor won’t start” and “it purrs along all afternoon.” Without one, most 13,500 BTU RV ACs need a 3,000W+ generator just to survive the startup surge. With a soft start, a 2,200W inverter generator can start and run a 13.5k unit.

Key takeaways

Do You Need a Soft Start Kit for Your RV Air Conditioner? — photo
  • A 13,500 BTU RV AC draws about 12.5–13.5 amps (1,500–1,800W) running, but its startup surge hits 2,800–3,500W for a split second.
  • A 2,000–2,200W inverter generator can’t deliver that surge — the compressor stalls, the generator overloads, and nothing cools.
  • A soft start kit ramps the compressor up gradually, cutting startup current by 65–75% — the most-cited figure is from Micro-Air’s EasyStart.
  • With a soft start, a 2,200W inverter generator reliably starts a 13.5k BTU unit; some owners even run 15k units on 3,000W generators.
  • Installation is a 1–2 hour DIY job inside the rooftop AC’s electrical box, and it does not void the AC warranty.
  • Cost is a few hundred dollars — far less than upgrading to a bigger, heavier generator.

The real problem: startup surge, not running watts

This is the single most misunderstood thing in RV power. Your Dometic or Coleman-Mach 13.5k BTU rooftop unit sips about 1,500–1,800 watts once it’s running — a 2,000W generator could handle that easily. But the instant the compressor kicks on, the motor demands its locked-rotor current: a massive inrush that lasts a fraction of a second but can hit 50+ amps — over 3,000 watts at 120V.

A Honda EU2200i (1,800W running, 2,200W peak) sees that surge, hits its hard overload limit, and trips. Inverter generators have a brick-wall limit: 2,200W means 2,201W trips it. The compressor never gets spinning, the generator faults, and you get to try again — same result.

I watched this play out at a rally a few summers back. A guy with a brand-new 2,200W inverter kept trying to start his 13.5k Dometic. Click, overload light, silence. He’d done the “watts math” (1,800 running watts < 2,200 generator watts) and couldn't understand it. The running watts were never the problem. The first half-second was.

What a soft start kit actually does

A soft start kit (also called a soft starter) sits in the compressor’s starting circuit and ramps the voltage up gradually instead of slamming the motor with full power instantly. Think of it like pushing a heavy cart: a soft start gives it a smooth shove instead of trying to teleport it to full speed.

The result, per Micro-Air’s published data on their EasyStart 364: 65–75% reduction in startup current versus the motor’s locked-rotor amperage. That 50-amp inrush becomes something like 15–18 amps — well within what a 2,200W inverter generator can deliver. The compressor still gets the same total energy to start; it’s just spread over a slightly longer ramp instead of one violent spike.

Bonus effects owners consistently report: the compressor starts noticeably quieter (no more thunk that shakes the whole RV), and it’s gentler on the generator — less voltage sag means your other electronics don’t brown out every time the AC cycles.

RV AC size Running watts Startup surge (no soft start) Min. generator without soft start Min. generator with soft start
13,500 BTU 1,500–1,800 2,800–3,500 3,000W+ 2,200W inverter
15,000 BTU 1,800–2,000 3,200–4,000 3,500W+ 3,000W inverter
9,000–11,000 BTU 1,000–1,300 2,000–2,500 2,500W+ 2,000W inverter

The Micro-Air EasyStart 364: the one everyone buys

The Micro-Air EasyStart 364 is the default recommendation across every RV forum, and for good reason — it’s the product with the most documented real-world results. Specs that matter:

  • Designed for 9k, 13.5k, and 15k BTU RV rooftop ACs (supports compressors up to 18,000 BTU / 1.5 tons).
  • Self-learning 4-stage start ramp — it runs a learning procedure over the first several compressor starts and optimizes the ramp for your specific unit.
  • Works with Dometic, Coleman-Mach, and most other RV rooftop brands.
  • Weatherproof enclosure, mounts inside the AC’s electrical box on the roof.
  • A Bluetooth version exists that shows you live startup amperage on your phone — genuinely useful for confirming it’s working.
  • Typically costs a few hundred dollars (the Bluetooth model runs a bit more).

Note: Micro-Air has been transitioning the 364 to the newer EasyStart Breeze, which is smaller and covers all RV AC sizes. Same function, easier install. Either way, buy from a reputable RV parts dealer — there are knockoffs floating around marketplaces that don’t do the learning ramp properly.

Pro tip: A soft start doesn’t reduce running watts. If your generator can’t sustain the AC’s 1,500–1,800W continuous draw (plus the converter charger and anything else running), a soft start won’t save you. Size for running watts first with our generator size calculator, then use the soft start to solve the surge problem.

Installation: what to expect

This is a solid DIY job if you’re comfortable with basic wiring and working on a roof. The outline:

  1. Kill all power. Unplug shore power, disconnect batteries, and confirm with a meter. Non-negotiable.
  2. Open the rooftop AC’s electrical box. It’s under the shroud — usually a handful of screws.
  3. Wire the soft starter into the compressor circuit per the included diagram (Dometic and Coleman-Mach have brand-specific instructions). It’s a handful of wire connections, clearly labeled.
  4. Mount the module inside the box with the included hardware.
  5. Run the learning procedure. This is the clever part: you start the compressor 5 times (with pauses between), and the unit optimizes its ramp each cycle. The Bluetooth model shows you the startup amps dropping with each cycle — owners report watching it fall from 50+ amps to the high teens.

Plan 1–2 hours, mostly spent being careful on the roof. And no — installing one does not void your AC warranty. It’s an add-on starting aid, the same category as the hard-start kits manufacturers themselves sell.

When a soft start isn’t the answer

Be honest about these cases:

  • Two ACs on one small generator. A soft start helps each unit start, but the running load of two 13.5k units (~3,200W) still needs a 3,500W+ generator or two paralleled inverters. Soft starts on both units plus paralleled 2,200W generators is a popular combo that works.
  • High altitude. Generators lose roughly 3% of output per 1,000 feet of elevation. At 7,000 feet your 2,200W generator is really a ~1,750W generator. Re-do the math for mountain camping.
  • Heat-soaked restarts. On the hottest afternoons the compressor works hardest. If you’re marginal, the soft start’s learning ramp handles most of this — but keep the 80% headroom rule in mind.

The alternatives, honestly priced

  • Bigger generator: a 3,000–3,500W inverter starts a 13.5k AC without a soft start. Costs more, weighs 100+ lbs vs. ~47 lbs for a 2,200W unit, burns more fuel. If you already own the small generator, the soft start is cheaper.
  • Paralleled inverters: two 2,200W units with a parallel kit give ~4,400W. Great flexibility (run one when you don’t need AC), but you’re buying a second generator.
  • Hard start kit: a capacitor-based booster, cheaper ($20–$40) but cruder — it doesn’t reduce inrush the way a true soft starter does, and many RVers who tried both say the soft start is in another league.
Do You Need a Soft Start Kit for Your RV Air Conditioner? — photo

Will a 2200 watt generator run a 13500 BTU RV air conditioner?

Not reliably without a soft start — the compressor’s 2,800–3,500W startup surge trips the generator’s overload. With a soft start kit (like the Micro-Air EasyStart 364) cutting inrush by 65–75%, a 2,200W inverter generator starts and runs a 13.5k unit comfortably.

Does a soft start kit reduce running watts?

No. It only reduces the startup surge — the brief inrush when the compressor first kicks on. Running watts stay the same, so your generator must still handle the AC’s 1,500–1,800W continuous draw plus other loads.

Does installing a soft start void my RV AC warranty?

No. A soft start is an add-on starting aid in the same category as manufacturer-sold hard-start kits. It’s a common, widely accepted modification in the RV community.

How long does it take to install a soft start on an RV AC?

About 1–2 hours for a careful DIYer: opening the rooftop unit’s electrical box, wiring the module into the compressor circuit, mounting it, and running the 5-cycle learning procedure. Basic wiring comfort and safe roof access are the prerequisites.

Can a soft start let me run two RV air conditioners on one generator?

Only if the generator can handle both units’ combined running watts (~3,000–3,600W for two 13.5k units). Soft starts solve the surge problem for each compressor, but running load is unchanged — you’d need a 3,500W+ generator or two paralleled inverters.

What’s the difference between a soft start and a hard start kit?

A hard start kit adds a capacitor that boosts starting torque but doesn’t meaningfully reduce inrush current. A true soft starter electronically ramps voltage to cut startup current by 65–75%. For small-generator RV use, the soft starter is the effective solution.

If you already own a 2,000–2,500W inverter generator and a rooftop AC, a soft start kit is one of the highest-value upgrades in RVing: a few hundred dollars, an afternoon on the roof, and suddenly the small quiet generator you love runs the AC all summer. That’s a trade I’ll take every time. For the rest of the RV power math — converter draw, battery charging, running a second AC — our generator calculators have you covered.